Current
SCPI Commands :
FETCh:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LE2M:CURRent
CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LE2M:CURRent
READ:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LE2M:CURRent
- class CurrentCls[source]
Current commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tol: float or bool: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.Bluetooth.Measurement.MultiEval.Scount#Modulation CMDLINKRESOLVED]) exceeding the specified limits, see ‘Modulation limits (LE) ‘.
Delta_F_299_P_9: float or bool: Frequency deviation value Δf2 above which 99.9% of all measured Δf2 values occur
Freq_Accuracy: float or bool: No parameter help available
Freq_Drift: float or bool: No parameter help available
Max_Drift: float or bool: No parameter help available
Freq_Dev_Avg_F_1: float or bool: No parameter help available
Freq_Dev_Min_F_1: float or bool: No parameter help available
Freq_Dev_Max_F_1: float or bool: No parameter help available
Freq_Dev_Avg_F_2: float or bool: No parameter help available
Freq_Dev_Min_F_2: float or bool: No parameter help available
Freq_Dev_Max_F_2: float or bool: No parameter help available
Nominal_Power: float or bool: Average power during the carrier-on state
Mod_Ratio: enums.ResultStatus2: Modulation ratio Δf2 avg / Δf1 avg
Freq_Offset: float or bool: No parameter help available
Init_Freq_Drift: float or bool: No parameter help available
- class ResultData[source]
Response structure. Fields:
Reliability: int: ‘Reliability indicator’
Out_Of_Tol: float: Out of tolerance result, i.e. the percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.Bluetooth.Measurement.MultiEval.Scount#Modulation CMDLINKRESOLVED]) exceeding the specified limits, see ‘Modulation limits (LE) ‘.
Delta_F_299_P_9: float: Frequency deviation value Δf2 above which 99.9% of all measured Δf2 values occur
Freq_Accuracy: float: No parameter help available
Freq_Drift: float: No parameter help available
Max_Drift: float: No parameter help available
Freq_Dev_Avg_F_1: float: No parameter help available
Freq_Dev_Min_F_1: float: No parameter help available
Freq_Dev_Max_F_1: float: No parameter help available
Freq_Dev_Avg_F_2: float: No parameter help available
Freq_Dev_Min_F_2: float: No parameter help available
Freq_Dev_Max_F_2: float: No parameter help available
Nominal_Power: float: Average power during the carrier-on state
Mod_Ratio: float: Modulation ratio Δf2 avg / Δf1 avg
Freq_Offset: float: No parameter help available
Init_Freq_Drift: float: No parameter help available
- calculate() CalculateStruct[source]
# SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LE2M:CURRent value: CalculateStruct = driver.bluetooth.measurement.multiEval.modulation.lowEnergy.le2M.current.calculate()
Returns current, average, absolute min (xmin) , absolute max (xmax) , and max modulation results for LE uncoded PHY (LE 1M PHY, LE 2M PHY) , see ‘Square TX Measurement - modulation statistics’. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() ResultData[source]
# SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LE2M:CURRent value: ResultData = driver.bluetooth.measurement.multiEval.modulation.lowEnergy.le2M.current.fetch()
Returns current, average, absolute min (xmin) , absolute max (xmax) , and max modulation results for LE uncoded PHY (LE 1M PHY, LE 2M PHY) , see ‘Square TX Measurement - modulation statistics’. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.
- read() ResultData[source]
# SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LE2M:CURRent value: ResultData = driver.bluetooth.measurement.multiEval.modulation.lowEnergy.le2M.current.read()
Returns current, average, absolute min (xmin) , absolute max (xmax) , and max modulation results for LE uncoded PHY (LE 1M PHY, LE 2M PHY) , see ‘Square TX Measurement - modulation statistics’. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.